CROWN MA5002VZ MA500VZ REPAIR
PROBLEM: BOTH CHANNELS IN PROTECT
This unit had an active pip card
removed the pip card and retested, both channels came out of protect
PIP card was damaged do to pluging in incorrectly, amp was fine